Daniel Series 500 Liquid Turbine Meter
Reliability in mobile fuel operations
Daniel Series 500 Liquid Turbine Flow Meter is a portable self-contained flow meter that serves the need for highly accurate flow measurement in tanker truck off-loading. It can also be mounted to loading arms to monitor the performance of other meters during loading operations in marketing terminals, and then easily removed when the verification is complete.
High accuracy measurement is achieved by using a bladed rotor that turns at a speed proportional to rate of flow. The rotation of the rotor is sensed by electrical pickoffs mounted on the meter body. The resultant signal is used as an input to the intrinsically safe electronic totalizer, which displays flow rate and total volume. All electronics are located in the water-tight aluminum housing and are easily accessible from the outside.
Daniel Series 500 Liquid Turbine Meter is versatile and adds a new level of reliability to the measurement of various refined and light hydrocarbon products, including gasoline and diesel fuels.
|
- Lightweight design for portability
- High accuracy and repeatability
- Integral mounted intrinsically safe electronics providing flow rate, reset and non-reset totalizers
- Battery Powered
- Fully Programmable
- Watertight to IP65 (NEMA 4X)
- TTMA flanged meter body
- Available in 3" and 4" line sizes
- Simple and easy to maintain
- Stainless steel bearings
- Password protected totalizer settings
- Limited warranty
Meter performance
- Sizes 3" and 4"
- Linearity: ± 0.25%*
- Repeatability: ± 0.02%*
*Under pressure condition with full line of liqui
Process parameters
- Temperature Ratings
- Process: 0°C to 60°C (32°F to 40°F)
- Ambient: -40°C to 70°C (-40°F to 58°F)
Pressure ratings and connections
- Maximum Allowable Working Pressure: 75 psig
Ingress protection rating
Pick-off specifications
- Type: 2-wire reluctance
- Resistance: 650 - 950 Ohms
- Inductance: 250 mH max
- Output: Sinusoidal 40mV p-p minimum @minimum flow
- Truck off-loading
- Marketing terminal check metering
|
|
|
|